Im new in GAD (Global Active Device) and i read the GAD Admin Guide – but, sorry, i did not understand what they try to tell me in that virtual HORCM-Instance. They talk about „HORCM_VCMD“ and after that description stops. Here is what you need (i think so and i hope thats correct). Instance starts, pairdisplay works….i know, its technical, but c’mon your are an admin and thats not a student guide. Take the comments out of the config 😉

System 1 without a SVM

HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 11304 -1 3000

HORCM_CMD
#dev_name
\\.\IPCMD-IP-of-Your-Box-31001
HORCM_VCMD (new entry)
# redefine Virtual DKC Serial# as unitIDs
322222 (Serial of your primary System with a "3" as first number)
HORCM_LDEV
#dev_group dev_name Serial# CU:LDEV(LDEV#) MU#
system1 system1lun0 322222 05:10 h1 

HORCM_INST
#dev_group ip_address service
system1 IP-of-your-Horcmserver 11305

System 2 with the SVM virtualize System 1.

HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
localhost 11305 -1 3000

HORCM_CMD
#dev_name
\\.\IPCMD-IP-of-Your-Second-Box-31001
HORCM_VCMD
# redefine Virtual DKC Serial# as unitIDs
322222
HORCM_LDEV
#dev_group dev_name Serial# CU:LDEV(LDEV#) MU#
system1 system1lun0 322222 05:10 h1 (VIRTUAL!!!! Ldev from the SVM)
HORCM_INST
#dev_group ip_address service
system1 IP-of-your-Horcmserver 11304